Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

ATULVSANGHAVI4014 5a7472111d6a770d04c65e99 Products https://www.technocolor.in

Techno Color Corporation Is Producing S.O.Dyes....

  • 2022-04-13T17:05:29

Techno Color Corporation Is Producing S.O.Dyes. Most Of The Dyes Are Spray-Dried With Our Recently Commissioned Spray Dried Plant. The Waste Water Generated From The Production Process Is Mainly The Washings Of The Spray Dried Plant And The Reactors, Which Gets Collected In 25 M3 Capacities RCC Underground Collection Tank From This Tank, The Waste Water Is Pumped To 3 X 5 M3 Capacities R.C.C Stirred Tanks, Three Such Tanks Are Available In Series. The Waste Water Is Checked For pH. (There are 2 X 10 M3 Capacity HDPE Underground Tanks In Reserve. In Most Cases, It Is Neutral And If Not, It Is Corrected Either With HCl Or Caustic Lye Depending On The pH Value To Get The Resultant pH Within 6.5 – 8.5. It Is Then Treated With Diluted Ferrous Sulphate Solution And The pH Is Compensated To Form Small Flocks. It Is Then Treated With Polyelectrolyte Solution To Precipitate The Coagulated Mass. The Resultant Coagulated Mass Is Then Filtered In Nutsche Filter. The Clear Liquid Is Allowed To Flow Either In Underground 10 M3 HDPE Tank Or Underground 25 M3 R.C.C tank. The Contents Are Checked For COD. The Treated Waste Water Is Aerated Further By Diffuse Aeration System, If Required. The Treated Waste Water, Okay In All Respect, Is Pumped To G.I.D.C. Drainage System Through Clarifier Containing Activated Carbon Bed. For More Info Visit Us On- techno-color.com

Techno Color Corporation Is Producing S.O.Dyes. Most Of The Dyes Are Spray-Dried With Our Recently Commissioned Spray Dried Plant. The Waste Water Generated From The Production Process Is Mainly The Washings Of The Spray Dried Plant And The Reactors, Which Gets Collected In 25 M3 Capacities RCC Underground Collection Tank From This Tank, The Waste Water Is Pumped To 3 X 5 M3 Capacities R.C.C Stirred Tanks, Three Such Tanks Are Available In Series. The Waste Water Is Checked For pH. (There are 2 X 10 M3 Capacity HDPE Underground Tanks In Reserve. In Most Cases, It Is Neutral And If Not, It Is Corrected Either With HCl Or Caustic Lye Depending On The pH Value To Get The Resultant pH Within 6.5 – 8.5. It Is Then Treated With Diluted Ferrous Sulphate Solution And The pH Is Compensated To Form Small Flocks. It Is Then Treated With Polyelectrolyte Solution To Precipitate The Coagulated Mass. The Resultant Coagulated Mass Is Then Filtered In Nutsche Filter. The Clear Liquid Is Allowed To Flow Either In Underground 10 M3 HDPE Tank Or Underground 25 M3 R.C.C tank. The Contents Are Checked For COD. The Treated Waste Water Is Aerated Further By Diffuse Aeration System, If Required. The Treated Waste Water, Okay In All Respect, Is Pumped To G.I.D.C. Drainage System Through Clarifier Containing Activated Carbon Bed. For More Info Visit Us On- techno-color.com

  • 2022-04-13T17:05:29

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us